8
Lamp Switches
Ballast Power
Cold Temperature Operation
The BarFly is designed to operate at temperatures from 14F to 122F (-10C to +50C).
In cold temperatures, the xture may not strike the lamp(s). Switch the xture to OFF.
Make sure the onboard dimmer is full up and re-strike.
Once operating for a few minutes, the Lamps should re-strike instantly.
It is normal for the lamp to require a few minutes to achieve full light output even at
room temperature.
Troubleshooting
If the xture does not strike after two or three attempts, turn off the xture.
With the power switch in the ON position, the red light should be on. If it is not,
Voltage is not present. Check your power feed. The onboard dimmer should be full up,
turned completely clockwise. All lamp switches should be in the ON position.
Check lamp contact. Once everything has been checked, re-strike.
Warning! To Ensure Proper Operation
ALWAYS TURN OFF THE FIXTURE BEFORE
connecting or disconnecting lamps. After the lamps are
properly installed, the in-line switch can be turned on.
The BarFly xtures require 100-240VAC 50/60 Hertz
on an earth grounded circuit. The electronic Ballast
operates at a high frequency of 47kHz. The BarFly is
lightweight, icker-free and dead-quiet.
The BarFly 400D has four Lamp Switches which allow for
individual lamp operation. Each switch controls one lamp.
Turning off 2 lamps equals a one f-stop reduction in light output
without color shift.